Every photonic quantum computing claim eventually meets the same question: how big must the device be before a classical computer can no longer keep up? A preprint posted on 9 November 2026 by Jean Senellart, Pascale Senellart, and colleagues at Quandela — with Esperanza Cuenca Gomez at NVIDIA — proposes a single yardstick and measures it with an open-source GPU library. The yardstick is the “simulability frontier”: the device size at which their fastest exact sampler draws one sample per second on one NVIDIA H100 GPU. On that yardstick the frontier sits at 38.3 single photons, 31.0 entangled photons from a single emitter, 50.0 vacuum–single-photon superpositions at half brightness, and 41.5 squeezed inputs at a mean photon number of 0.5. The boundary: this is a benchmarking paper, not a hardware result. No device is claimed to cross the frontier, and the frontier is a lower bound on classical capability, not a hardness threshold.

Why the old numbers could not be compared

For single-photon boson sampling alone, published thresholds for when classical simulation gives up range from 50 to 98 photons — a spread wide enough to contain two different answers to the same question. The published numbers do not measure the same thing: they rest on different tasks, different sampling guarantees, and different hardware assumptions. Other devices are characterised by still other quantities, and complexity results give no wall-clock time at all.

“Classical simulation” names several tasks with very different costs. Strong simulation returns every output probability and is limited by memory — on one H100 it reaches only 13 single photons. Estimating a single probability to additive error costs polynomial time but yields no samples. Exact sampling draws outcomes from exactly the device’s output distribution, and it is the task the paper measures: it is what a device does, and it is the only task whose cost compares across kinds of light, since the cost of an approximate sampler depends on the error it is allowed and on the test that checks it. Approximate sampling — how the largest squeezed-light experiments have actually been matched classically — is deliberately excluded. The frontier is defined for Haar-random interferometers with twice as many modes as photonic inputs, and every number comes with an audit in the open-source library photonic-engines.

The frontier in numbers

The headline table, at twice as many modes as photonic inputs, is short enough to quote in full. Single photons: 38.3. Photons from one quantum emitter, entangled into a linear cluster state: 31.0. Vacuum–single-photon superpositions at half brightness, each source emitting a photon with probability one half: 50.0. Squeezed light at 0.5 photons per squeezer: 41.5 — this last figure from a timing model fitted to measurements, not direct timing.

The differences come from how many photons each input carries and from the overhead of its sampler. Squeezed light and superpositions reach more photonic inputs than single photons because their cost grows with the number of photons detected, and many of their inputs carry no photon at all: a sample at the squeezed frontier holds about 21 detected photons on average, against 38.3 for single photons. The emitter frontier is lower because entanglement costs: a train of photons from one emitter is a matrix-product state whose bond dimension is set by the emitter’s spin, so each sampling step needs permanents whose entries are matrices rather than numbers, raising the effective exponential base from 1.82 for single photons to 1.94 for the emitter.

And because the cost grows as roughly 1.82 to the power of the photon number, doubling the machine’s speed moves the frontier by only about one photon, whereas a better algorithm changes the growth rate.

Coherence is the surprise

The most striking result is not any single frontier value but what happens when the light is made coherent. A lossy single photon and a coherent superposition of vacuum and one photon can have exactly the same brightness — the same probability that a source yields a detected photon — and differ only in coherence: the lossy photon is an incoherent mixture of vacuum and one photon, the superposition is a coherent one. At fixed brightness of one half, the frontier falls steadily from 64.2 for the incoherent source to 50.0 for the coherent one, a drop of 14.2 ± 0.2 photonic inputs

The authors are careful about what this does and does not prove. Six points falling steadily do not show that the sampler is optimal, so they do not prove that the 14.2 is intrinsic to coherence — a better sampler might close the gap.

Feed-forward barely moves it

Feed-forward — measuring some modes mid-circuit and letting the result choose the interferometer applied to the rest — is the feature that turns a sampler into a computer, and it is widely assumed to make classical simulation much harder. On this yardstick it barely does. With one, two, and three modes measured mid-circuit, the single-photon frontier stays at 38.3, 38.2, and 38.1, against 38.3 without feed-forward. It drops to 37.6 at four measured modes and to 33.8 at eight. The cost grows as two to the power of the photons read mid-circuit — small when few modes are measured.

One non-linear site — a phase proportional to the square of the photon number in one mode — lowers the single-photon frontier by 2.2, and each further site by about 2.1 more: 36.0, 34.3, 30.3, and 21.4 for one, two, four, and eight sites. But the result is provisional: the cost jumps reflect the sampler’s branch expansion, not the physics.

Loss and distinguishability follow one law

For inputs of fixed photon number, loss and partial distinguishability act through a single law: a photon adds to the cost only if it is detected and indistinguishable from the others. A lossy sample is a lossless sample on the photons that survive, whose number follows the binomial law; averaging the exponential cost over that law gives the frontier at transmission η. For the emitter, with β = 1.94, the law matches every measured value within 0.3 photonic inputs.

The measured table is worth having. At transmission 1, 0.9, 0.8, 0.7, and 0.5, the single-photon frontier runs 38.3, 41.2, 45.0, 49.2, and 64.2 — counted in emitted photons. The emitter runs 31.0, 33.6, 36.8, 40.9, and 53.5. Partial distinguishability enters the same formula: at visibilities of 1, 0.95, 0.9, and 0.8, the single-photon frontier runs 38.3, 39.0, 40.0, and 41.8.

Squeezed light is the exception. Its photon number is not fixed, and loss acts on its covariance, thinning a photon-number distribution broader than Poissonian. Its frontier rises faster with loss than the law allows — by a factor of 2.33 at 50 percent transmission, where the law allows at most a factor of two There is also a transmission threshold: if the device keeps only the trains in which all photons are detected, its rate falls as η to the power of n while the classical cost grows as β to the power of n — so below η = 1/β it never crosses: below 0.55 for single photons and 0.51 for the emitter.

Tick by tick, the register sets the cost

Some devices process photons tick by tick — an emitter train through a fixed interferometer, or photons circulating in a time-bin loop — and for those the size that matters is the state the simulator must carry from one tick to the next, not the length of the train. For emitter trains that register is the emitters’ spins: about 21 emitters reach one tick per second, however many photons each emits. Extrapolating from 18 emitters, at 28 milliseconds per tick, gives 21 to 22 emitters at one tick per second with the matrix-product update, 19 to 20 with a direct expansion.

For time-bin loops the register is the photon content of the loop, and the frontier becomes a loop delay rather than a photon number. A single loop is efficiently simulable for single photons at any delay, so those results are reaches, not hardness boundaries; hardness needs several loops. For one emitter the reach is 4,204 photons at a delay of six time bins and 2,166 at eleven — lower bounds, since table construction on the CPU stopped the runs. Superpositions reach 267.4 photons at delay one and 21.4 at delay eight; squeezed light falls fastest with delay, dropping below its demultiplexed frontier of 41.5 at a delay of about six.

Replaying a real experiment

The paper’s most concrete test is a replay of a published squeezed-light experiment: the 216-mode, three-loop processor of Madsen and colleagues, which published its samples. For the low-brightness run — squeezing parameter 0.53, 1.044 million samples, at most 53 detected photons — drawing the same number of exact samples from its published model takes 39 to 44.5 hours on one H100, or 0.133 seconds per sample when replaying the run’s own patterns. The model reproduces the device’s photon-number distribution within the statistical noise of 10,000 samples — one marginal, not the full distribution.

For the high-brightness run — squeezing parameter 1.10, 124 detected photons on average — the median sample costs 2.4 × 10¹⁶ H100-seconds, or 7.5 × 10⁸ H100-years, in the double-double arithmetic its exactness requires. No other squeezed-light device is within reach of exact sampling — but the classical simulations that have matched them are approximate, so the exact frontier must not be read as “safe up to n* squeezers.”

The same section turns the question around for the devices that exist today. The typical sample of every current single-photon and emitter-based machine lies inside the one-hertz frontier. But a fast, lossy device can outpace exact reproduction of its output stream long before its typical sample is hard, because the rare trains in which many photons survive dominate the cost. A three-source entangled device at 1 GHz with 48 photons in 96 modes needs about thirty H100 at 20 percent end-to-end transmission to reproduce its exact output stream in real time — 29 at 20 percent, 580 at 30 percent — while its typical train, with about ten detected photons, lies far inside the frontier. For one quantum-dot emitter, today’s clusters of ten to fourteen photons are seventeen to forty-four emitted photons short of the frontier at any transmission.

The honest boundary

Four qualifications should accompany these numbers. First, the paper is a preprint, posted 9 November 2026, and as of this writing has not appeared in a peer-reviewed journal. Its results are, however, unusually checkable for a preprint: the library is open source, the result files behind every number are in the repository, and each sampler is validated against a separate simulator that shares no code with it.

Second, the frontier is exact sampling only, on one machine, with uniform imperfections and photon-number-resolving detection. For squeezed-light devices, whose relevant classical competitors are approximate, the frontiers overstate the classical difficulty. And the squeezed frontier comes from a timing model, not direct measurement — a calibrated model, but a model.

Third, there is a second frontier that has nothing to do with speed. In double precision, the samplers meet their error criterion — relative error below 10⁻³ at each step of a sample — up to about 55 single photons and about 62 detected photons of squeezed light, so near those sizes the number format, not the number of GPUs, sets the frontier. Fourth, energy: at 38 photons an exact sample costs 7.3 × 10⁻² watt-hours on the H100, and the energetic advantage falls below twelve photons on measured board energy, against 15 in an earlier analysis.

What to watch next

The follow-ups that would matter most follow directly from the gaps above. First, the frontier as a living number: the library is open source and audited, so independent groups can run it, break it, and move the frontier with better algorithms. Second, whether the coherence gap survives a better sampler: the 14.2-photon drop is measured for this sampler, and whether it is intrinsic to coherence is explicitly open. Third, the non-linear-site results, whose jumps with phase come from the sampler’s branch expansion rather than the physics of the state. Fourth, approximate sampling: the frontier that matters for squeezed-light devices is the approximate one, and this paper deliberately does not measure it. Fifth, the devices themselves: today’s emitter clusters are seventeen to forty-four photons short of the frontier.

The lasting contribution may not be any single frontier value but the reframing: “how big before classical simulation gives up” is a question with a reproducible answer, measured in samples per second on a stated machine with stated code. The frontier is a lower bound, and it will move — and when it does, everyone will be able to say by how much, and why.

Sources and further reading

  • Jean Senellart, Benjamin Stott, Stephen Wein, Esperanza Cuenca Gomez, Pascale Senellart, Shane Mansfield & Pierre-Emmanuel Emeriau, “The simulability frontiers of photonic quantum computing,” arXiv:2611.12876, posted 9 November 2026. Preprint, not peer-reviewed. Primary source for all figures here: photonic-engines open-source GPU library of exact samplers (MIT licence, version 0.2.1); one NVIDIA H100 PCIe GPU; Haar-random interferometers with m = 2n modes and photon-number-resolving detectors unless stated; frontier at one exact sample per second: 38.3 single photons, 31.0 entangled photons from one emitter (linear cluster), 50.0 vacuum–single-photon superpositions at α = π/4, 41.5 squeezed inputs at 0.5 photons per squeezer (timing model); coherence scan at fixed brightness p = 1/2, frontier 64.2 to 50.0, drop 14.2 ± 0.2; feed-forward K = 1, 2, 3 → 38.3, 38.2, 38.1; one non-linear site at φ = π/2 lowers the frontier by 2.2; loss table (Table 4) and distinguishability visibilities as quoted; tick-by-tick frontier ≈ 21 emitters; Madsen et al. 216-mode replay, low-brightness run 39–44.5 hours on one H100, high-brightness median sample 2.4 × 10¹⁶ H100-seconds; strong simulation limited to 13 single photons at m = 2n; double-precision accuracy range to about 55 single photons; energetic frontier below twelve photons on measured H100 board energy.
  • Companion papers cited for the sampler derivations: the exact sampling rules in a companion paper (ref. [52] in the preprint) and the additive-error estimator in a second companion paper (ref. [51]); neither is quoted for figures here.
  • Prior work on classical boson sampling costs: P. Clifford & R. Clifford, “The classical complexity of boson sampling,” Proc. SODA 2018, and “Faster classical boson sampling,” Phys. Scr. 99, 065121 (2024); A. Neville et al., “Classical boson sampling algorithms with superior performance to near-term experiments,” Nat. Phys. 13, 1153 (2017) — the sources behind the published 50-to-98-photon threshold range quoted in the preprint.
  • Note on verification: all quantitative values here are taken directly from the arXiv HTML full text of the preprint (v1), read on 24 November 2026, including the abstract, Sections 2–9, Tables 1, 3, and 4, and Figures 1–4. The preprint’s acknowledgements disclose that the photonic-engines code and the manuscript were written with the assistance of generative models from Anthropic (Claude), with the authors taking responsibility for the whole. No market-size figure, commercial claim, or investment judgement appears here; the site’s Terms carry the not-investment-advice disclaimer. This article concerns a benchmarking and simulation paper, not a hardware result; no device is claimed to cross any frontier, and no single-photon source result from this desk’s other coverage is conflated with it.